Applications
❖ Vertical windows
❖ Roofing
❖ Curved roofing
❖ False ceiling
❖ Machinery protection guards
❖ Room partitions
Thickness (mm) | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 |
Weight (kg/mq) | 2.4 | 3.6 | 4.8 | 6.0 | 7.2 | 9.6 | 12 | 14.4 |
Width (mm) | 2.050 – 2.500 | |||||||
Length (mm) | 6.100 | |||||||
Color | Light Transmission (LT) % | |||||||
Clear | 91 | 90 | 90 | 90 | 88 | 86 | 80 | 80 |
Bronze | 44 | 48 | 51 | 50 | ||||
Opal | 53 | 50 | 40 | 38 | ||||
Blue | 11 | |||||||
Green | 28 | 42 | ||||||
Linear thermal expansion 0,065mm/m°C | ||||||||
Fire Reaction | EuroClass B-s1,d0 upon request. Additional test results supplied upon request |
Thermal Insulation U (W/m2K) | ||||||||
Thickness (mm) | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 |
PoliComp | 5.66 | 5.49 | 5.33 | 5.21 | 5.09 | 4.84 | 4.61 | 4.35 |
Glass | 5.87 | 5.82 | 5.80 | 5.77 | 5.71 |
Acoustic Insulation (dB) | ||||||||
Thickness (mm) | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 |
Value | 25 | 26 | 27 | 28 | 29 | 31 | 33 | 34 |
Application of flat sheets
Solid polycarbonate sheets can be installed in most PVC, wood, steel and aluminium structures and frames. The frame must hold the sheet in place while allowing it to expand. The choice of sheet thickness depends on the load value required. According to the size of the sheet, from table A, the effective area and also the thickness will be calculated.
Table B can be used to calculate the thickness of the sheet to be used according to the size of the sheet (AREA) and the required load value.
The values shown in table B (positive and negative loads) have been calculated for sheets fixed on four sides, with a maximum bend value (rise) of 50mm.
Sheet size. (Tab. A)
Sheet Width (m) | ||||||||
Sheet Length (m) |
0,25
|
0,50
|
0,75
|
1,00
|
1,25
|
1,50
|
1,75
|
2,00
|
0,25
|
A1
|
A1
|
A1
|
A1
|
A1
|
A1
|
A1
|
A1
|
0,50
|
A1
|
A2
|
A3
|
A4
|
A4
|
A4
|
A4
|
A4
|
0,75
|
A1
|
A3
|
A5
|
A6
|
A7
|
A7
|
A7
|
A7
|
1,00
|
A1
|
A4
|
A6
|
A8
|
A9
|
A9
|
A10
|
A10
|
1,25
|
A1
|
A4
|
A7
|
A9
|
A10
|
A11
|
A12
|
A13
|
1,50
|
A1
|
A4
|
A7
|
A9
|
A11
|
A13
|
A14
|
A15
|
1,75
|
A1
|
A4
|
A7
|
A10
|
A12
|
A14 |
A16
|
A17
|
2,00 |
A1
|
A4
|
A7
|
A10
|
A13
|
A15 |
A17 |
A18 |
2,25 |
A1
|
A4
|
A7
|
A10
|
A13
|
A16 |
A18 |
A19 |
2,50 |
A1
|
A4
|
A7
|
A10
|
A14 |
A16 |
A19 |
|
2,75 |
A1
|
A4
|
A7
|
A11
|
A14 |
A16 |
A19 |
|
3,00 |
A1
|
A4
|
A7
|
A11
|
A14 |
A17 |
A19 |
|
3,25 |
A1
|
A4
|
A7
|
A11
|
A14 |
A17 |
||
3,50 |
A1
|
A4
|
A7
|
A11
|
A14 |
A17 |
||
3,75 |
A1
|
A4
|
A7
|
A11
|
A14 |
A17 |
||
4,00 |
A1
|
A4
|
A7
|
A11
|
A14 |
A17 |
||
4,25 |
A1
|
A4
|
A7
|
A11
|
A14 |
A17 |
||
4,50
|
A1
|
A4
|
A7
|
A11
|
A14 |
A17 |
||
4,75 |
A1
|
A4
|
A7
|
A11
|
A14 |
A17 |
||
5,00 |
A1
|
A4
|
A4
|
A7
|
A11
|
Choice of thickness. (Tab. B)
load (daN/m2) |
|||||
Area |
60
|
80
|
100
|
120
|
140
|
A1
|
3
|
3
|
3
|
3
|
3
|
A2 |
3
|
3
|
4
|
4 |
4 |
A3
|
4
|
4
|
4
|
4
|
5
|
A4
|
4
|
4
|
5
|
5
|
6
|
A5
|
5
|
5
|
5
|
5
|
6
|
A6
|
5
|
6
|
6
|
6 |
8
|
A7
|
6
|
6
|
8
|
8
|
8 |
A8
|
6
|
6
|
8
|
8
|
8 |
A9
|
8
|
8
|
8
|
8
|
10 |
A10
|
8
|
8
|
10
|
10
|
10 |
A11
|
10
|
10
|
10
|
10 |
12 |
A12
|
10
|
10
|
10
|
12 |
12 |
A13
|
10
|
10 |
10
|
12 |
|
A14
|
10
|
12
|
12
|
||
A15
|
10
|
12
|
12
|
||
A16
|
10
|
12
|
12
|
||
A17
|
12
|
12
|
|||
A18
|
12
|
12
|
|||
A19
|
12
|
Application of cold-curved sheets
Policomp® is ideal for building integral arch or tunnel structures. The minimum bend radius is 150 times the thickness of the sheet. The choice of sheet thickness depends on the bend radius but also on the width of the sheet.
Minimum Bend Radius
Thickness (mm) | 2 |
3 | 4 | 5 | 6 | 8 | 10 | 12 |
Radius (mm) | 300 | 450 | 600 | 750 | 900 | 1.200 | 1.500 | 1.700 |